PEM electrolyser design & simulation software

Big science. Bright ideas.

Small cell.Big what if?

Meet your hydrogen idea before you build it. Explore a cell, grow it into a stack, and understand what could make it better — design intelligence for people who spend real money on prototypes.

In plain EnglishThink of it as a flight simulator for hydrogen machines. You describe how your electrolyser is built; we show how much electricity it will waste, and where, before you spend money building it.

3-day trial · no card · 5 assessments · then plans from £99/mo

+−Water inA tiny water-splitting cellHydrogen H₂Oxygen O₂
Water + electricity → a new possibilityTouch & explore

Electricity helps separate water into hydrogen and oxygen. This picture is a teaching illustration, not an experiment.

1

Pick a starting point

Choose a preset or describe your own cell design.

2

Turn the dials

Change any input and watch the physics respond instantly.

3

Understand the trade-offs

Curves, loss breakdowns, and honest limits — all in one place.

The science, in one breath

Water has a secret.
Electricity can unlock it.

Water is made of hydrogen and oxygen. An electrolyser uses electricity to separate them — a thin membrane keeps the gases apart while tiny charged particles move through it.

The part engineers actually pay for is knowing how well any particular design does that job. That's what PROTONYX computes: the voltage your cell needs, where the energy goes, and what to change first.

Get to know the science
For curious minds & serious engineers

Easy to enter.
Room to go deep.

Plain-language explanations sit beside every technical term. Expert controls are there when you want them. Neither hides the assumptions — every result lists what it assumed and what it can't promise.

2H₂O → 2H₂ + O₂

Water → hydrogen + oxygen. Electricity supplies the energy.

Try it — 10 seconds

Squeeze more hydrogen from the same electricity

Thinner = electricity flows more easily.

Harder = more hydrogen per hour, but more heat.

84 %

of the electricity becomes hydrogen

16 % is lost as heat · cell voltage 1.76 V

Illustration only — a simple toy model, not PROTONYX output. Sign up to run the real physics on your own design.

The idea in 30 seconds

How water becomes hydrogen

Water inAnodeCathodeMembraneO₂H₂ ×2

PROTONYX works out how much voltage this takes for your materials and dimensions, and where every wasted millivolt goes.

The cost of finding out by buildingPX-100Sheet 01 of 03
01Capital in a prototype that misses spec£50–200kMachining, membrane, catalyst, assembly, test rig time
02Calendar lost per rebuild cycle6 weeksAnd the diagnosis is usually inconclusive
03Loss terms quantified in millivolts5Anode and cathode activation, membrane ohmic, interfacial contact, mass transport
04Subsystem mechanisms modelled on top4Acoustic, electrostatic, magnetic and mist — each acting through the five
05Time to a complete assessment< 30 s

Figures are indicative of single-cell R&D builds at 200–800 cm² active area. Your own history will be more accurate — the console keeps it.

02 · What the engine returns

Solved, not estimated

Tafel kinetics at both electrodes. Nernst corrected for temperature and differential pressure. Membrane conductivity is yours to supply, and we tell you when the figure you entered is the 30 °C reference value rather than one for your operating temperature. Faraday yield on your active area.

A loss budget you can act on

Five loss terms — anode activation, cathode activation, membrane ohmic, interfacial contact, mass transport — each in millivolts at your target current density, ranked, with the component responsible named. The four subsystem mechanisms are modelled as their effect on those terms, not as separate ones.

Interpretation, in writing

The computed numbers are read back as a senior electrochemist would read them: what dominates, why your material choices caused it, what to change first, and what will degrade.

Ranked by leverage

Every input re-solved against realistic alternatives and ranked by millivolts of swing — so you know which decisions matter and which you can stop arguing about. Paste the rig sweep afterwards and the model grades itself.

03 · The workflow
01

Specify

Cell, membrane, anode, cathode, current collectors, operating point, scale-up and targets — plus the acoustic, electrostatic and magnetic subsystems where your plan includes them. Every field is optional; what you leave blank is filled from literature and declared on the result.

02

Solve

Sixty-point polarisation sweep scaled to your operating point, with every overpotential term resolved separately.

03

Interpret

The numbers are explained against your components, with ranked changes and expected deltas in mV or kWh/kg.

04

Iterate, then validate

Overlay any number of variants, fabricate the one you can already defend, then paste the measured sweep back in and see the residual in millivolts.

04 · Architectures

Standard PEM, and the ones nobody models

Mist and aerosol feed, acoustic streaming, electret dipole alignment, magnetic OER facilitation. Treated as physics with literature-referenced corrections and an explicit confidence grade — not silently ignored, and not oversold.

Standard liquid-fedZero-gap CCMHigh-pressure cathodeMist-fedAerosol-fedAcoustic-enhancedElectret-assistedMagnetic-coupledSingle cellMulti-cell stackMulti-stack system
05 · Questions

PEM electrolyser simulation, answered

What is PROTONYX?

PROTONYX is web-based design and simulation software for PEM (proton exchange membrane) water electrolysers. You describe a cell or stack and it computes the polarisation curve, a loss breakdown in millivolts, efficiency, specific energy in kWh/kg H₂ and hydrogen production rate, then writes a scientific interpretation of the result.

Who is PROTONYX for?

It is for hardware engineers, electrolyser start-ups and research labs who want to evaluate a PEM electrolyser design before paying to build it — typically single-cell R&D builds of 200–800 cm² active area, through to multi-cell stacks and multi-stack systems on the higher plans.

What does a PEM electrolyser assessment include?

Each assessment returns a 60-point polarisation curve; the voltage loss split into anode activation, cathode activation, membrane ohmic, interfacial contact and mass transport, each in mV; cell and system efficiency on HHV and LHV bases; kWh/kg H₂; hydrogen production rate; a ranking of which inputs move the result most; and a written interpretation. Every result lists the assumptions it made and any warnings about its validity.

How accurate is the simulation?

Cell-level physics uses established electrochemistry — Tafel kinetics, Nernst thermodynamics, membrane ohmic resistance with temperature correction, and mass transport — and you can paste a measured polarisation sweep to see the residual against the model in millivolts. It is a steady-state, spatially averaged model: it does not model gas crossover, transients or resolved flow fields, and scale-up constants are literature-typical estimates labelled as such. The model limits page lists every simplification.

Which electrolyser architectures can it model?

Standard liquid-fed PEM, zero-gap catalyst-coated membrane (CCM) and high-pressure cathode designs, plus mist-fed operation. Acoustic, electrostatic (electret) and magnetic subsystems are available on the Enterprise plan and are presented as model hypotheses to validate on hardware, not established gains.

How long does an assessment take?

Under 30 seconds. The physics solves almost instantly; the written interpretation streams in while you read the numbers.

Is there a free trial?

Yes. Every new account gets a free 3-day trial with no card required, including Cell plan features and 5 assessments. After the trial, plans start at £99 per month.

How much does PROTONYX cost?

Cell is £99 per month (15 assessments / month); Pro is £299 per month (unlimited assessments); Scale is £899 per month (unlimited assessments); Enterprise is £2,500 per month (unlimited assessments). All plans are monthly and can be cancelled any time.

Is my design data kept private?

Your designs are stored in your account and visible only to you unless you create a share link. The physics runs on PROTONYX servers; to write the interpretation, your design specification and computed results are sent to a third-party AI model provider.

How is it different from a spreadsheet model or CFD?

It is more complete than a spreadsheet and far faster than CFD: a full single-cell electrochemical model with a ranked loss budget and sensitivity analysis in under 30 seconds. Where you need resolved flow or current-density fields, CFD is still the right tool.

Full list of what the engine does not model: model limits.

Ready for your next “what if”?

Plans from £99/month. A 3-day no-card trial — not a free tier.

Find your plan →